Innova SDS50 SDS-Tech: Steering Angle Sensor Calibration

    Purpose

    To guide users how to perform the Steering Angle Sensor Calibration function while using the Innova SDS50 SDS-Tech Tablet Scan Tool.

    Introduction

    Modern vehicles come equipped with various safety features such as Vehicle Stability Control System (VSC), Lane Keep Assist (LKA), Autonomous Emergency Braking (AEB), and other Advanced Driver Assistance Systems (ADAS). These systems rely on the accuracy of the Steering Angle Sensors (SAS) to help drivers maintain control of their vehicles.

    Performing a calibration of the steering angle sensor is necessary after activities like wheel alignment, collision repairs, or component replacement, as these can potentially affect the toe and thrust angle. Calibration ensures that these systems have precise information about the vehicle's position on the road, allowing them to make necessary corrections. If the SAS is not properly calibrated, the stability system of the vehicle may malfunction and eventually become disabled.

    Procedure

    Step 1 - Connect Innova SDS50 SDS-Tech Tablet Scan Tool to the vehicle and select 'Workshop Tools' function

    First, connect the Innova SDS50 SDS-Tech Tablet Scan Tool to your vehicle via the On-Board Diagnostics (OBD) connector to retrieve the vehicle's information, such as Vehicle Identification Number (VIN) and model.

    Then, select the 'Workshop Tools' section.

    Step 2 – Select the 'Steering Angle Sensor Calibration' function

    The Innova SDS50 SDS-Tech Tablet Scan Tool offers a range of features, including 16 Service Reset functions as illustrated in the image. To initiate the Steering Angle Sensor Calibration function, you can choose the 'Steering Angle Sensor Calibration' item from the list.

    Step 3 – Select function responsible for the Steering Angle Sensor Calibration

    To access the reset function, select the 'Steering Angle Adjustment' item.

    NOTE: The name of the Steering Angle Sensor Calibration function varies by manufacturer, year and model.

    Step 4 – Perform the SAS Calibration function

    In the function, there are some conditions that must be met first before performing the ‘Steering Angle Sensor Calibration’. If not, the resetting function will be unsuccessful.

    Select ‘Next’ button to go to the next step.

    Wait for the Scan Tool to perform the SAS Calibration on the vehicle and make sure to follow the note on the Scan Tool screen.

    Check the result of the function. Select ‘Exit’ button to finish the function if completed. If the SAS Calibration function was not completed, verify the condition/notes and repeat the Calibration function.

    Reference Video

    Steering Angle Sensor Calibration

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.

Still need help? Contact Us Contact Us